OphthalmologyA.R.C. Laser CETUS
A.R.C. Laser CETUS
Réf : CETUS

Cataract surgery with the Nano Laser

CETUS

Cataract surgery with the Nano Laser

  • 100 % Photofragmentation
  • 100 % no ultrasound
  • 100 % single use handpieces
  • Your most affordable choice to enter the prestigious PREMIUM laser segment.
Pulses with 4 Nanoseconds and 3 to 7 mJ per pulse will crack the nucleus.
Pulses with 4 Nanoseconds and 3 to 7 mJ per pulse will crack the nucleus.

Cataract surgery becomes 100 % laser surgery with the CETUS.

Nano-Laser Surgery means PREMIUM

  • Do you offer premium lenses within your portfolio?
  • Do you want to offer a premium service with a laser option?
  • Do you want to avoid the expensive and time consuming effort with femto laser assisted cataract surgery?

The Nano-Laser can be operated with a femto laser to do the rhexis, or without the expensive femto laser. In either case, you benefit by performing full laser cataract surgery. 

Easy OR Integration

The A.R.C. Nano-Laser is very compact which means that it only needs a fraction of a Femto's space.

 

  • The Nano-Laser is easily adapted to your Phaco Ultrasonic system by simply plugging in the cutters tubing.
  • Inexpensive single-use handpieces eliminate the need for cleaning, sterilization and tuning of the phaco handpiece.
  • Complete single-use-sets are available.
  • The Nano-Laser is maintenance free.

Upgrade your Phaco with a laser system as easy as 1-2-3

More information:

• CETUS - Flyer (PDF)

 

Nano-Laser ist gentle, safe and easy to use

  • Ultrasound energy has been implicated in the pathogenesis of endothelial cell loss.
  • This manual laser treatment creates no thermal gradient.
  • The laser avoids mechanical side effects caused by the oscillating phaco tip – minimum risk for a capsular rupture.
  • Eliminates the risk of cross contamination - Single-use handpieces guarantee highest sterility.
  • LOCS P- and -C criterias can be fulfilled.

No more expensive handpieces.
No more cross contamination.
No more need for a Femto.

Lasers attract patients

With the introduction of Lasik, laser became the number one tool in ophthalmology and patient satisfaction.

  • Patients have never been so highly attracted by any other means of surgery.
  • Patients demand laser surgery - especially in ophthalmology.
  • Lasers are advanced technology and contribute to a high value image of your practice.
  • There is no other treatment with the appeal of laser based surgery.
  • It’s only a small step for you to get started with PREMIUM laser surgery.

 

The A.R.C. Nano-Laser emulsifies the cataract with pulses that are gentle and effective.

  • No moving parts,
  • no temperature gradient
  • and Cataract-Laser-Surgery is yours upon request.

Inexpensive, single-use, lightweight laser handpieces eliminate the need for cleaning, sterilization and tuning of the heavy phaco handpiece.

Nano-Laser with coaxial handpiece

Coaxial with two different sleeves allows small incisions of 2.2 or 2.6 mm.
Your other hand assists with your manipulator. Coaxial fluid management works the same way as conventional ultrasound phaco.

The Nano-Laser surgery benefits from an extremely little energy into the eye.

Cetus Nano-Laser Handstück
Aspiration, irrigation and laser through one single-use handpiece

 

Immediate practice integration

The CETUS Nano-Laser can help you elevate your practice by adding a laser system to your OR with an easy Click 'n Go System to your existing phaco machine. 
This could drive growth through increased volume and premium conversion.

  • Attract more patients by means of laser procedure
  • Convert more patients to premium procedures and IOLs

Our Cetus is designed to fit into any OR / Practice with minimal effort, offering an intuitive and seamless workflow from start to finish.

  • Facilitates quick handling with a touchscreen
  • Allows efficient surgical planning and individual settings
  • Convenience of adaptability and integratability

Specifications

Max. Energy 10 mJ
Operating mode pulsed
Shot frequency up to 10 Hz
Wavelength 1064 nm
Pulse energy 3 mJ to 10 mJ
Pulse length 5 ns
Control 7“ touch screen
Power requirements

110-240 Vac, 650 VA, 50 to 60 Hz

Dimensions 135*478*421 mm (device housing)
Weight 12 kg

Gentle cataract surgery using a nano laser

References

Germany

Prof. Dr. med. Dr. h.c. N. Schrage, Cologne, Germany
PD Dr. Gangolf Sauder, Charlottenklinik Stuttgart, Germany
Dres. J. Hauck, G. Rohrbach, I. Rohrbach, Düsseldorf, Germany
Dr. M. Knabe & Dr. L. Blomberg, Augenzentrum Hildesheim,Germany
Dr. Amir-Mobarez Parasta, Augenzentrum Munich, Germany
PD Dr A Liekfeld, Ernst von Bergmann Klinikum Potsdam, Germany
Dr. Ahmed Galal & Dr. Bilgic, Augenarztpraxis Bremerhaven, Germany
Dr. Rheinard Lehmann, Maria Hilf Augenklinik Mönchengladbach, Germany
Prof. Dr. S. Grisanti, Klinik für Augenheilkunde Lübeck, Germany
Dr. M.Schweer, Operative Augenarztpraxis Hanstedt, Germany
Prof. Dr. Wiegand, Asklepios Klinik Nord Hamburg, Germany
Dr. B. Gabler, Gemeinschaftspraxis Donauwörth, Germany
Dr. med. Erik Domeier, Augen Praxisklinik Lübeck, Germany
Dr. med. Bernd Hörster, Mönchengladbach, Erkelenz, Germany
Dr. med. Martin Winter, Augenzentrum Mitte, Bremen, Germany
Prof. Dr. med. Karl Heinz Emmerich, Darmstadt, Germany

International
Prof. Walid Zbiba, Tunisia 
Prof. A. J. Kanellopoulos, MD,Athens, Greece
Dr. J.C. VryghemBrusells, Belgium
Assoc. Prof. Ivan Tanev, MD, PhDSofia, Bulgaria
Prof. l. Mastropasqua,Chieti-Pescara, Italy
Dr. Jan Witkiewicz, MD, Warsaw, Poland
Dr. Kunihiro Nagahara, Kagawa, Japan